The North American Generator Forum (NAGF) was founded in 2009 as a vehicle for generator owners and/or operators to address issues related to registration, compliance, standards development and other NERC-related topics. In 2013, the North American Generator Forum, Inc. became a non-profit, dues-based corporation.

We provide entities who are generator owners and operators in North America a means to collaborate and communicate with FERC, NERC, the Regional Entities, the Canadian Provinces and other organizations with missions similar to ours, with the ultimate goal of improving the reliability of the bulk power system. 

More information is available at: http://generatorforum.org/

RECENT ACTIVITY

Said: : "I believe that there are two educational challenges in this respect. Firstly, onsite NG storage presents insurmountable cost, logistical and security issues. I estimate that onsite NG storage for a typical 2x1 F-class combined cycle pla...
Said: : "The comment was made during the discussion of increased utility reliability reliance on the gas industry. The OER made it clear that FERC has no jurisdiction over the gas industry. The OER stated that each utility company will need to ass...
Said: : "Yes, that comment really caught my eye, and outlines how much educating we still have to do as an organization and as an industry about our capabilities and realities that many others just don't understand."
Said: : "Was the comment, "GOs should take responsibility for ensuring they have enough onsite gas storage to ride through an outage of undetermined duration," made seriously?"
Said: : "I am going to assume that you have several generators with name plate ratings less than 20 MVA, but the output of all the generators connected to the BES on the common bus is greater than 75 MVA--so you have one applicable facility. That...
Said: : "All good advice on this thread. Here's my two cents: While a discrete list is not required, the following activities would augment the assurance that an entity has indeed identified all BCA devices (nothing hiding in a closet). These ac...
Said: : "Similar to Andy's approach we worked with our Engineering, Operations, SCADA, and Asset Infrastructure groups to identify the Low Impact BCS, reviewed one-lines, did a site visit for each of our flavor of wind farm (based on OEM), and rev...
Said: : "We have identified our Low Impact BCS by consulting with the various work groups (power production, Transmission, SCADA/EMS, IT, Security) and visiting relevant sites. We then used network diagrams to identify where we need LEAP. In resp...
Said: : "We had discussions to identify which systems meet the criteria of a BES Cyber System and then did walk downs to identify the associated BES Cyber Assets. We did not conduct passive or active scans of the controls network because we didn't...
Said: : "This is a good discussion. We are also doing walkdowns and document all Programmable Electronic Devices, then log on the spreadsheet whether they are BES or non-BES and a justification as to why. John's approach seems like a great one -...
Said: : "Hi Amy; We have walked each of our hydro plants, all Low CIP, with a team made up of a Project Manager, SMEs from our generation group, SMEs from our control network group, our Compliance department SME, and plant operations. We are usin...

FEATURED DISCUSSION


To get the most from your experience as a member of North American Generator Forum,
a Groupsite powered by the Groupsite.com platform for groups,
it is important that you have an understanding of how this Groupsite
will empower you to share, communicate and network securely within this Membership Group.



The video below provides a brief 3-minute introduction to Groupsites.
Please take a moment to view it fully. It will help you to become actively
involved in making this a productive Membership Group.













For additional, more detailed, instruction we encourage you to view the
full demo tour.



Thank you,



North American Generator Forum